Open at preset intervals whether or not condensate is present. Simple, but incorrect settings can waste air or leave water behind.
Compressed Air Condensate Management
Automatic drains remove liquid condensate from compressed air equipment before it accumulates, carries downstream or causes corrosion. Different drain designs balance reliability, air loss and maintenance.
Automatic drains open or discharge when condensate collects in a receiver, filter, separator or dryer. Timed drains open on a schedule, float drains respond to liquid level, and zero-loss drains discharge condensate without intentionally venting compressed air.
Timed
Open at preset intervals whether or not condensate is present. Simple, but incorrect settings can waste air or leave water behind.
Level-Sensing
Open when condensate reaches a set level, reducing unnecessary discharge.
Zero-Loss
Use level sensing and controlled discharge to remove liquid without intentional compressed-air loss.
| Condition | Recommended Starting Point | Why | What to Verify |
|---|---|---|---|
| Receiver tank | Reliable automatic drain sized for debris and condensate load | Prevents standing water and corrosion | Verify pressure rating and service access. |
| Water separator | Drain compatible with separator flow | Removes captured bulk liquid | A blocked drain can send water downstream. |
| Coalescing filter | Low-loss drain with good sealing | Protects filter performance and reduces air waste | Check for oil, dirt and emulsion. |
| Refrigerated dryer | Manufacturer-approved drain | Removes dryer condensate continuously | Drain failure is a common cause of water downstream. |
Check operation, alarms, drains, differential pressure and visible contamination.
Record service dates, measurements, element changes and unusual conditions.
Confirm that the component still meets the process requirement under peak operating conditions.
Bulk Water
Remove entrained liquid before it reaches dryers and fine filters.
Condensate Treatment
Treat oily condensate collected from drains in oil-lubricated systems.
Complete Treatment
Browse the complete air-treatment category.
Provide the equipment model, airflow, pressure, temperatures, application and current symptoms.
It removes condensate from compressed air equipment without requiring an operator to open a manual valve.
It is a level-sensing drain designed to discharge condensate without intentionally venting compressed air.
Possible causes include debris on the valve seat, a failed seal, incorrect timer settings or a damaged valve.
The drain may be clogged, undersized, unpowered, isolated or incorrectly programmed.
Common locations include receiver tanks, aftercoolers, separators, filters and refrigerated dryers.
Oil-lubricated systems may produce oily condensate that requires treatment before discharge.